Model Z710 DC
Model Z710 DC motor is our newly developed Z series DC motor, the center height of 770 mm. Due to the structure and properties of Z710 type motor is unique, there is some difference between the medium and Z series DC motor.
Two, the use of conditions
1 motor can be mounted on the environmental condition is bad situations, but must choose proper cooling and protection level, to keep the machine clean inside.
2 Should not contain acid, alkali, the insulation of the motor and reversing property damage to the electricity gas cooling air.
3 motor such as the use of the ship and the wet tropics and working environment with salt spray, humidity, should be a separate agreement.
4 Rated power motor is at an altitude of less than 1000 meters, the ambient air temperature is not more than 40C under the conditions of.
5 The power supply of motor using static rectifier power supply, also can use DC generator.
Three, the product structure
The motor frame by polygonal laminations, has the advantages of small volume, light weight, suitable for silicon controlled rectifier power supply. The motor insulation class F. Solventless varnish vacuum pressure impregnation treatment using motor ( VP ", make the winding insulation has good moisture resistance capability, mechanical strength and excellent thermal conductivity. Armature core made of silicon steel sheets which are stacked together, with good magnetic properties of motors with rolling bearings, stable operation. Mounting the motor in accordance with GB997 and IEC34-7 " motor structure and installation form code "
Standard IM1001 end cover bearing, foot mounting, horizontal, cylindrical uniaxial extension
Can be derived with IM1002 cover type bearing, foot mounting, horizontal, cylindrical shaft
Motor protection grade according to GB4942.1 and IEC34-5 " motor shell protection grade " standard, shell protection grade standard motor has IP22 and IP44 two. Motor cooling methods according to GB1993 and IEC34 - 6 " motor cooling method " standard. The standard motor has ICl7, IC37 and ICW37A86 three. If you need other protection grade, the cooling method can be negotiated. The standard type of cooling air entrance in the motor drive end ( non commutator end ).
Four, product performance
1, the motor of the quota for continuous conduction mode ( SI ).
2 ,Standard of rated voltage the motor of 440V, 660V, 750V three.
3,Excitation mode the motor is excited, exciting windings have four lead terminals, divided into two groups of two series excitation voltage is 220V, the parallel excitation voltage is 110V. The actual excitation voltage motor, should be based on the actual motor excitation current reaches the rated value as the standard, the motor allow forced excitation, forcing voltage shall not exceed 500V. Strong excitation, excitation current can be instantaneous slightly more than the rated excitation current, but the excitation current is stable, not more than.
4, overload capacity of the motor:
The first kind of DC motor ( Class A ) can withstand short time required under the table ( one minute) overload.
The base of the percentage |
The percentage of rated current |
For occasional use |
Often use |
100 |
200 |
175 |
200 |
160 |
150 |
300以上 |
140 |
125 |
Second types of DC motor ( B ) can withstand short time required under the table ( one minute) overload.
The base of the percentage |
The percentage of rated current |
For occasional use |
Often use |
100 |
200 |
175 |
200 |
200 |
160 |
300以上 |
175 |
140 |
Second types of DC motors ( class B ) shall bear the following continuous load:
( 1 ) with 115% rated load for continuous operation at rated armature voltage and rated speed range, the load, temperature will be higher, other properties may be specified and rated to run under the conditions of different.
( 2 ) rated armature voltage and rated speed range, continuous operation at rated load, followed by 125% of rated power for two hours, the temperature does not exceed the prescribed value, other properties may be specified and the rated operating under different values of.
* short-term overload capacity for occasional use is rarely occurred or in the case of an emergency, the motor bearing capacity of more than continuous rated load in a minute, suggest the instantaneous circuit breaker device according to the short-time overload the occasional use of setting. Short-time overload ability.
* * use often refers as part of normal work of the motor cycle, to bear the beyond the rated load.
* * * After the short-time overload operation, must be running with light load, so the load motor cycle load RMS value does not exceed its continuous rating. On second types of DC motors ( B ), occasionally use overload allows up to 2.5 times ( at rated base speed ), no more than 15 seconds ( but in consultation with the company ).
5, the current rate of change
In all the speed and load current changes, motor rate ( di / DT ) allows up to 200 times the rated current / S.
6, the noise and vibration
The motor " noise measurement methods and limits " in line with the national standard GBl0069.3.
" The motor vibration measurement method and limits " in line with the national standard GBl0068.2.
Five, capacity selection
The first kind of DC motor ( class A ):
Detailed data on this kind of motor see technical data sheet, the user can according to the required capacity, speed and voltage selected motor model and the specification.
Second types of DC motor ( B ):
Power, current technology of data of this kind of motor than a technical data sheet of the value is low, but the actual value to be set by the user and manufacturing company.
In addition to the motor specifications listed technical data, the user can according to the specific needs and manufacturing company consultations, derived from other specifications of DC motor.
Six technicial date(class A)
Z710-320 is suitable for cooling Applied to the cooling types of IC17,IC37,ICW37A86
Number |
Rated voltage speed |
Power |
Rated
Current |
Efficiency |
The maximum
speed |
Excition power |
Rotation
Inertia |
Ventilate |
440V |
660V |
750V |
Air quantity |
wind presssure |
1 |
480 |
|
|
800 |
1963 |
92.6 |
1100 |
8.5 |
289 |
4.0 |
0.85 |
2 |
560 |
|
|
1000 |
2473 |
93.3 |
1100 |
10 |
296 |
4.6 |
1.08 |
3 |
|
530 |
|
1000 |
1621 |
93.4 |
1100 |
10 |
289 |
4.4 |
1.0 |
4 |
|
745 |
|
1250 |
2021 |
93.7 |
1200 |
8.4 |
289 |
5.1 |
1.3 |
5 |
|
|
645 |
1250 |
1775 |
93.9 |
1100 |
9.8 |
296 |
5.0 |
1.26 |
6 |
|
860 |
|
1500 |
2423 |
93.8 |
1100 |
8.7 |
296 |
6.0 |
1.75 |
7 |
|
|
845 |
1500 |
2129 |
93.9 |
1200 |
8.2 |
289 |
5.9 |
1.7 |
Z710-400 is suitable for cooling
Applied to the cooling types of IC17,IC37,ICW37A86
Number |
Rated voltage speed |
Power |
Rated
Current |
Efficiency |
The maximum
speed |
Excition power
Air quantity |
Rotation
Inertia |
Ventilate |
440V |
660V |
750V |
Air quantity |
wind presssure |
1 |
380 |
|
|
800 |
1967 |
92.4 |
1000 |
9.3 |
337 |
4.2 |
0.93 |
2 |
445 |
|
|
1000 |
2440 |
93.2 |
1000 |
10.9 |
344 |
4.7 |
1.13 |
3 |
|
422 |
|
1000 |
1624 |
93.3 |
1000 |
10.6 |
337 |
4.6 |
1.08 |
4 |
|
590 |
|
1250 |
2019 |
93.8 |
1100 |
8.7 |
337 |
5.1 |
1.3 |
5 |
|
|
515 |
1250 |
1774 |
93.9 |
1000 |
10.5 |
344 |
5.1 |
1.3 |
6 |
|
690 |
|
1500 |
2418 |
94 |
1000 |
9.13 |
344 |
5.9 |
1.7 |
7 |
|
|
680 |
1500 |
2125 |
94.1 |
1100 |
8.5 |
337 |
5.7 |
1.6 |
Z710-500 is suitable for cooling Applied to the cooling types of IC17,IC37,ICW37A86
Number |
Rated voltage speed |
Power |
Rated
Current |
Efficiency |
The maximum
speed |
Excition power
Air quantity |
Rotation
Inertia |
Ventilate |
440V |
660V |
750V |
Air quantity |
wind presssure |
1 |
305 |
|
|
800 |
1975 |
92.1 |
800 |
10.4 |
397 |
4.4 |
1.0 |
2 |
360 |
|
|
1000 |
2446 |
92.9 |
800 |
11 |
404 |
4.8 |
1.17 |
3 |
|
337 |
|
1000 |
1625 |
93.2 |
800 |
11.6 |
397 |
4.7 |
1.13 |
4 |
|
470 |
|
1250 |
2021 |
93.7 |
1000 |
10.1 |
397 |
5.2 |
1.35 |
5 |
|
|
410 |
1250 |
1777 |
93.8 |
800 |
11.4 |
404 |
5.2 |
1.35 |
6 |
|
550 |
|
1500 |
2419 |
94 |
800 |
10.6 |
404 |
6.0 |
1.75 |
7 |
|
|
530 |
1500 |
2125 |
94.1 |
1000 |
10.9 |
397 |
5.8 |
1.65 |
Z710-630 is suitable for cooling
Applied to the cooling types of IC17,IC37,ICW37A86
Number |
Rated voltage speed |
Power |
Rated
Current |
Efficiency |
The maximum
speed |
Excition power
Air quantity |
Rotation
Inertia |
Ventilate |
440V |
660V |
750V |
Air quantity |
wind presssure |
1 |
240 |
|
|
800 |
1988 |
91.4 |
700 |
11.9 |
475 |
4.8 |
1.17 |
2 |
280 |
|
|
1000 |
2458 |
92.5 |
700 |
13.3 |
482 |
5.3 |
1.4 |
3 |
|
268 |
|
1000 |
1633 |
92.8 |
700 |
12.7 |
475 |
5.0 |
1.26 |
4 |
|
370 |
|
1250 |
2027 |
93.4 |
800 |
11.8 |
475 |
5.5 |
1.49 |
5 |
|
|
325 |
1250 |
1783 |
93.5 |
700 |
12.7 |
482 |
5.5 |
1.49 |
6 |
|
435 |
|
1500 |
2425 |
93.7 |
700 |
12.1 |
482 |
6.3 |
1.92 |
7 |
|
|
430 |
1500 |
2129 |
93.9 |
800 |
11.1 |
475 |
6.0 |
1.75 |
Z710-800 is suitable for cooling
Applied to the cooling types of IC17,IC37,ICW37A86
Number |
Rated voltage speed |
Power |
Rated
Current |
Efficiency |
The maximum
speed |
Excition power
Air quantity |
Rotation
Inertia |
Ventilate |
440V |
660V |
750V |
Air quantity |
wind presssure |
1 |
185 |
|
|
800 |
2008 |
90.5 |
550 |
14.5 |
576 |
5.5 |
1.49 |
2 |
220 |
|
|
1000 |
2477 |
91.7 |
550 |
14.2 |
583 |
5.8 |
1.65 |
3 |
|
210 |
|
1000 |
1645 |
92.1 |
550 |
13.7 |
576 |
5.5 |
1.49 |
4 |
|
290 |
|
1250 |
2038 |
93 |
700 |
13.6 |
576 |
6.1 |
1.81 |
5 |
|
|
255 |
1250 |
1793 |
92.9 |
550 |
13.8 |
583 |
6.0 |
1.75 |
6 |
|
345 |
|
1500 |
2436 |
93.3 |
550 |
13.4 |
583 |
6.8 |
2.21 |
7 |
|
|
325 |
1500 |
2138 |
93.3 |
700 |
13.6 |
576 |
6.5 |
2.03 |
Seven, outline and mounting dimension table
Pipe ventilation ( IC17 )
The half pipe ventilation ( IC37 )
Mode |
|
Foot size |
Shaft extension
Size |
The outlet box Size |
H L C HD |
A |
B |
K |
HA |
AB |
BB |
AA |
BA |
BA' |
D |
E |
AD |
Z710-320 |
710 1890 355 1415 |
1400 |
1120 |
56 |
40 |
1540 |
1610 |
200 |
475 |
535 |
250 |
410 |
1028 |
Z710-400 |
710 1970 355 1415 |
1400 |
1250 |
56 |
40 |
1540 |
1690 |
200 |
475 |
535 |
250 |
410 |
1028 |
Z710-500 |
710 2070 355 1415 |
1400 |
1250 |
56 |
40 |
1540 |
1790 |
200 |
475 |
535 |
250 |
410 |
1028 |
Z710-630 |
710 2250 355 1415 |
1400 |
1400 |
56 |
40 |
1540 |
1920 |
200 |
475 |
535 |
250 |
410 |
1028 |
Z710-80 |
710 2420 355 1415 |
1400 |
1600 |
56 |
40 |
1540 |
2090 |
200 |
475 |
535 |
250 |
410 |
1028 |
With a backpack, air cooler(ICW37A86)
Mode |
|
Foot size |
Shaft extension
Size |
The outlet box Size |
Cooler dimension |
H |
L |
C |
HD |
A |
B |
K |
HA |
AB |
BB |
AA |
BA |
BA' |
D |
E |
AD |
LA |
AE |
HV |
Z710-320 |
710 |
1890 |
355 |
1415 |
1400 |
1120 |
56 |
40 |
1540 |
1610 |
200 |
475 |
535 |
250 |
410 |
1028 |
2390 |
1830 |
3044 |
Z710-400 |
710 |
1970 |
355 |
1415 |
1400 |
1250 |
56 |
40 |
1540 |
1690 |
200 |
475 |
535 |
250 |
410 |
1028 |
2470 |
1830 |
3044 |
Z710-500 |
710 |
2070 |
355 |
1415 |
1400 |
1250 |
56 |
40 |
1540 |
1790 |
200 |
475 |
535 |
250 |
410 |
1028 |
2500 |
1830 |
3044 |
Z710-630 |
710 |
2250 |
355 |
1415 |
1400 |
1400 |
56 |
40 |
1540 |
1920, |
200 |
475 |
535 |
250 |
410 |
1028 |
2630 |
1830 |
3044 |
Z710-80, , |
710 |
2420 |
355 |
1415 |
1400 |
1600 |
56 |
40 |
1540 |
2090 |
200 |
475 |
535 |
250 |
410 |
1028 |
2800 |
1830 |
3 |
|